O menu

0.4kV Tropical Climate GCK Draw-out Switchgear for Grid Step-Down

Inventário:
SKU: 3108178628
Modelo: GCK 600*1000*2200

{{ variable.name }}

{{ value.name }}

0.4kV Tropical Climate GCK Draw-out Switchgear for Grid Step-Down

GCK 600x1000x2200 draw-out switchgear cabinet for tropical grid step-down distribution
Product Summary: The GCK 600×1000×2200 is a low voltage draw-out switchgear cabinet for 0.4kV power distribution systems. This tropical-grid configuration references a Rwanda electrical contractor project where 13 units supported voltage step-down and local grid power distribution for a 10-year design duration. The withdrawable module design allows each circuit to be withdrawn for maintenance without interrupting the main busbar supply.
0.4kVUp to 4000A50kA/1sIP40Withdrawable Modules

Key Features

Independent Withdrawable Circuits

Drawable functional units and a common busbar system let each circuit be withdrawn for maintenance without interrupting the main busbar supply, supporting quick component replacement and expansion.

50kA/1s Short-Time Withstand

The rated short-time withstand current is 50kA/1s for short-circuit breaking in 0.4kV networks.

Up to 4000A Rated Current

Rated current up to 4000A at 0.4kV and 50/60Hz supports incoming, outgoing, bus-tie control and circuit protection.

IP40 Indoor Protection

Standard protection is IP40 for indoor installation with natural ventilation. A higher protection class can be customized per site requirements.

Tropical Grid Case Reference

The Rwanda grid step-down case reports low energy loss, tropical climate adaptability and easy maintenance for 13 units over a 10-year design duration, supporting continuous and stable power supply.

Technical Specifications

ParameterSpecification
ModelGCK 600×1000×2200
Rated voltage0.4kV
Rated frequency50/60Hz
Rated currentUp to 4000A
Rated short-time withstand current50kA/1s
Protection classIP40, higher protection class customizable per site requirements
Dimensions600×1000×2200mm
Cooling methodNatural ventilation
InstallationIndoor
StructureDraw-out switchgear with common busbar system

Models and Options

The referenced model is GCK 600×1000×2200 with 0.4kV rated voltage and rated current up to 4000A. Circuit configuration and withdrawable units can be arranged for incoming, outgoing, bus-tie control and protection. IP40 is standard; a higher protection class can be customized per site requirements. Price, MOQ and lead time are not stated in the source data and should be confirmed by inquiry.

Materials and Structure

The cabinet uses cold-rolled steel sheet, copper busbar, molded case circuit breaker components and insulating epoxy parts. Drawable functional units are combined with a common busbar system for independent circuit withdrawal. The structure is compact and uses natural ventilation for indoor installation.

GCK low voltage switchgear assembly with withdrawable modules and copper busbar

Applications

The GCK cabinet is used for incoming, outgoing, bus-tie control and circuit protection in 0.4kV power distribution networks. Sectors include industrial plants, commercial buildings, data centers, photovoltaic power stations, power grids and infrastructure projects.

  • Industrial plants and commercial buildings requiring flexible circuit configuration.
  • Data centers and photovoltaic power stations needing reliable short-circuit breaking capacity.
  • Power grids and infrastructure projects requiring withdrawable maintenance access.
  • Rwanda project reference: voltage step-down and power distribution for a local grid with 13 units.

Customization

Protection class can be customized above standard IP40 per site requirements. Circuit configuration and withdrawable functional units can be arranged for project needs. System expansion is supported by the draw-out module design. Confirm specific site conditions with the supplier.

Case Study

Rwanda Grid Step-Down and Power Distribution

Client type: Electrical contractor
Country: Rwanda
Quantity: 13 units
Application: Voltage step-down and power distribution for local grid
Duration: 10 years
Result: Continuous and stable power supply
Highlight: Low energy loss, tropical climate adaptability, easy maintenance

FAQ

What is the rated voltage and frequency?

The GCK switchgear is rated for 0.4kV and 50/60Hz operation.

What is the maximum rated current?

The rated current is up to 4000A.

What is the short-time withstand current?

The rated short-time withstand current is 50kA/1s.

How does the withdrawable design help maintenance?

Each circuit can be independently withdrawn without interrupting the main busbar supply, supporting quick component replacement and expansion.

What protection class and cooling method are used?

Standard protection is IP40 for indoor installation with natural ventilation. A higher protection class can be customized per site requirements.

Which applications does this configuration suit?

It suits incoming, outgoing, bus-tie control and circuit protection in industrial plants, commercial buildings, data centers, photovoltaic power stations, power grids and infrastructure projects. The Rwanda case specifically covers local grid step-down and power distribution.

Inquiry Information

Contact: Samantha, Sales Manager
Email: samantha@teelectric.com
TEL: +86 13923783341
WhatsApp: +86 13360330142
Address: 16#, Fuheng Road, Hecheng Street, Gaoming District, Foshan, Guangdong, China

Foshan TE Electrical Co., Ltd. operates under ISO9001, ISO14001 and ISO45001 management systems. Share your project voltage, current, circuit quantity and site protection requirements for a suitable GCK configuration.

Image Filename and Alt Suggestions

  • gck-600x1000x2200-tropical-grid-front.jpg — alt: GCK 600x1000x2200 draw-out switchgear cabinet front view for grid step-down
  • gck-600x1000x2200-withdrawable-module.png — alt: Withdrawable functional units inside GCK low voltage switchgear cabinet
  • gck-600x1000x2200-busbar-assembly.jpg — alt: Copper busbar and circuit assembly of GCK switchgear cabinet