O menu

Deep Freezer Reefer Truck Holds -25°C with 120 mm Walls

Inventário:
SKU: 080092990X
Modelo: Reefer Truck

{{ variable.name }}

{{ value.name }}

SEO Title: Deep Freezer Reefer Truck Holds -25°C with 120 mm Walls

Meta Description: Deep freezer reefer truck holding -20 to -25C: 120 mm polyurethane walls, heated door seal, insulated T-floor return air and defrost control for ice cream runs.

URL Slug: /deep-freezer-reefer-truck

H1: Deep Freezer Reefer Truck Holds -25°C with 120 mm Walls

Deep Freezer Reefer Truck Holds -25°C with 120 mm Walls

Deep freezer reefer truck with thick insulated body panels
Insulated rear doors with multi-lip gasket on a deep frozen reefer body Deep freezer reefer truck parked for loading at a cold store dock

Product Summary

Deep-frozen work is not the same order as ordinary frozen work. This reefer truck is built for -20 to -25°C at the loading point, the regime used for ice cream and other products that cannot be allowed to soften, with 120 mm polyurethane walls instead of the 100 mm standard and a heated door seal where the specification calls for it. The body still covers a band such as -20 to +12°C, but the refrigeration unit is sized for the coldest set point required, so the coldest point on the route decides wall thickness, unit capacity and floor design.

Key Features

120 mm walls for deep-frozen workFRP 1.5-2.0 mm skins over polyurethane foamed under about 120 kPa; the 120 mm specification cuts the heat load at -25°C, while 100 mm remains standard for -18°C routes.
Heated door sealA multi-lip EPDM gasket with a heated seal option stops the gasket freezing to the stainless rear door frame after long deep-frozen runs.
Insulated floor and T-railsA 100-150 mm insulated floor with aluminium T-section rails keeps the return air path open under pallets, which is what prevents warm pockets in a deep-frozen load.
Defrost controlAutomatic hot-gas or electric defrost with a digital thermostat, so ice build-up on the evaporator is cleared on a schedule instead of during unloading.
Holds within plus or minus 1°CController with digital set point and cab display, high and low temperature alarms, and pull-down from 30°C ambient to 0°C in 30-60 minutes.
Ambient -20 to 45°CWorking ambient range across the model family, with tropical cooling available for 45°C operation in hot markets.

Technical Specifications

ItemSpecification
Deep-frozen set point-20 to -25°C at the loading point
Temperature band per bodyOne body can cover a band such as -20 to +12°C
Wall thickness120 mm for deep-frozen work; 80-120 mm range, 100 mm standard
Panel constructionFRP 1.5-2.0 mm both faces, polyurethane core 38-45 kg/m3, foamed under about 120 kPa
Floor100-150 mm insulated with aluminium T-section rails
Door sealMulti-lip EPDM gasket, heated seal for deep-frozen work
DefrostAutomatic hot-gas or electric defrost
RefrigerantR404A standard, low-GWP option on request
Temperature holdWithin plus or minus 1°C
Pull-downEmpty body from 30°C ambient to 0°C in 30-60 minutes
Body volume / pallets10-45 m3, 4-14 pallets (1,200 x 800 mm and 1,200 x 1,000 mm)
Body internal sizeLength 3,800-9,600 mm, width 2,000-2,450 mm, height 1,800-2,500 mm
MonitoringDigital set point, high and low temperature alarms, data logger with one to four sensors optional
Warranty12 months major components; unit under unit supplier terms

Models and Options

  • Unit type: non-independent, self-powered, electric standby or eutectic plates; capacity rises with body size, colder set point or hotter climate.
  • Doors: rear double doors standard; side door, strip curtain or roller shutter for multi-drop deep-frozen work.
  • Interior: shelving, cargo rails, LED light, drain plugs, stainless or galvanised meat rail where carcass work is planned.
  • Records: data logger with up to four sensors and a USB or printed output for receivers who ask for temperature history.

Materials and Structure

Skins are FRP/GRP 1.5-2.0 mm with a food-grade gel coat inside; the core is rigid polyurethane of 38-45 kg/m3. Rear door frames, posts, hinges, locks and handles are stainless steel, interior lining is food-grade FRP or stainless steel 304 with coved corners, and the partition wall, where fitted, is an insulated FRP panel in a stainless frame sealed at floor, walls and roof. Piping is copper with elastomeric insulation, and evaporator and condenser housings are aluminium or ABS.

Applications

  • Ice cream and frozen dessert distribution at -20 to -25°C.
  • Frozen meat, fish and ready meals moving from cold store to distribution centre.
  • Frozen product for pharmaceutical use, stated at -20°C in the project requirement.
  • Bakery and confectionery or chocolate transport in warm climates, where a colder set point protects the load.
  • Cold store to cold store shuttle runs and port transfer work.

Customization

The set point is turned into a set point and a hold time before the body and unit are sized, so a colder regime is quoted as a different build rather than an option on a standard truck. Left-hand or right-hand drive, Euro II to Euro V engines, tropical cooling, cold-start packages and a low-GWP refrigerant are confirmed at order.

Case Study

A batch of refrigerated trucks shipped to a food and pharmaceutical distributor in Ghana in February 2025 went through full ex-works inspection before dispatch, so the units were ready to run on arrival and client downtime was reduced. The distributor operates temperature-sensitive cargo across different climates and reported stable temperature control and strong climate adaptability.

FAQ

Why specify 120 mm walls instead of 100 mm?Wall thickness follows the set point. 100 mm is standard for -18°C frozen work; 120 mm is specified for deep-frozen -20 to -25°C service, where the larger heat load has to be controlled by the body and the unit together.
Is a heated door seal necessary?For deep-frozen work it is available as a specified item and prevents the gasket freezing to the stainless door frame, which protects the seal and keeps door opening quick at each stop.
What causes warm pockets in a deep-frozen load?Blocked return air is the usual cause, not a weak unit. T-section floor rails, an air chute on long bodies, bulkhead clearance and a painted load line keep the air path open.
Can the truck also carry chilled cargo?Yes. One body can cover a band such as -20 to +12°C, but the unit is sized for the coldest set point required, and simultaneous chilled and frozen loads call for a partitioned multi-temperature body.
How is the unit capacity chosen?Body volume, ambient, set point and door openings decide the unit. The 5 t class body is quoted at about 4,700 W, and a bigger body or a hotter climate takes a larger unit.
What is included in delivery?Invoice, packing list, bill of lading, certificate of origin, insurance, body test report and unit manual, shipped by RoRo or break-bulk under FOB, CIF or DAP terms, 30-40 working days from down payment.

Inquiry Information

Confirm the coldest set point on the route, the hold time required, the daily number of door openings and the ambient at loading. Sales engineers then fix wall thickness, unit capacity, floor design and interior layout before quoting.

Tel: +86-13083602803 · WhatsApp: +86-16638078903 · Email: info@elorry-ind.com · Zhengzhou City, Henan Province, China

Image Filename and Alt Suggestions

reefer-truck-deep-freezer-120mm-body.png — Deep freezer reefer truck with thick insulated body panels.
reefer-truck-deep-freezer-rear-doors.png — Insulated rear doors with multi-lip gasket on a deep frozen reefer body.
reefer-truck-deep-freezer-loading-dock.png — Deep freezer reefer truck parked for loading at a cold store dock.