O menu

Three-Phase Isolation Transformer for Data Center and Industrial Power

Inventário:
SKU: 9321849351
Modelo: FPIT

{{ variable.name }}

{{ value.name }}
Three-Phase Isolation Transformer for Data Center and Industrial Power
FPIT three-phase isolation transformer, 1 kVA to 5,000 kVA, CRGO core, copper or aluminum windings, Delta Wye Zig-Zag connection, IP21 or IP23 enclosure.
three-phase-isolation-transformer
Three-Phase Isolation Transformer for Data Center and Industrial Power
three-phase isolation transformer, FPIT isolation transformer, data center isolation transformer, industrial isolation transformer

Three-Phase Isolation Transformer for Data Center and Industrial Power

Model FPIT · 1 kVA – 5,000 kVA · CRGO core · IEC / IEEE / ANSI / UL

FPIT three-phase isolation transformer unit with powder-coated steel enclosure

Product Summary

The FPIT three-phase isolation transformer provides reliable galvanic isolation between primary and secondary circuits in three-phase power distribution systems. A low-loss grain-oriented electrical steel (CRGO) core with optimized magnetic circuit design reduces no-load losses and operating noise, while high-conductivity copper or aluminum windings carry the load current. Rated capacity spans 1 kVA to 5,000 kVA, with primary voltage up to 15 kV, secondary voltage from 120 V to 690 V, and Delta, Wye or Zig-Zag connections configured to your vector group.

Key Features

  • Galvanic IsolationReliable isolation between primary and secondary circuits, protecting downstream three-phase distribution equipment from electrical interference.
  • Low-Loss CRGO CoreHigh-quality grain-oriented electrical steel with an optimized magnetic circuit lowers no-load losses and operating noise.
  • Copper or Aluminum WindingsHigh-conductivity conductors with optimized winding structure and reinforced insulation for demanding duty cycles.
  • Flexible Connection and TapsDelta, Wye or Zig-Zag connection, customized vector group and tap range of ±2 × 2.5% for site voltage matching.
  • Thermal and Enclosure OptionsAN or AF cooling, Class F or Class H insulation, indoor or outdoor enclosure rated IP00, IP21 or IP23.
  • Standards and CertificationDesigned and manufactured according to applicable IEC, IEEE, ANSI and UL requirements, with CE certification covering isolation transformers.

Technical Specifications

PhaseThree Phase (single-phase units also available in the FPIT range)
Rated Capacity1 kVA – 5,000 kVA
Primary VoltageUp to 15 kV / Customized
Secondary Voltage120 V – 690 V / Customized
Frequency50 / 60 Hz
Cooling MethodAN / AF
Insulation ClassClass F / Class H
Temperature Rise80 K / 115 K / Customized
ConnectionDelta / Wye / Zig-Zag / Customized
Vector GroupCustomized according to application
Tap Range±2 × 2.5% / Customized
EnclosureIndoor / Outdoor
Protection DegreeIP00 / IP21 / IP23 / Customized
InstallationFloor-Mounted
Applicable StandardsIEC / IEEE / ANSI / UL, according to market requirements

Models and Options

The FPIT range covers general-purpose, drive isolation, K-factor, three-phase and single-phase isolation transformers. Three-phase units are supplied with AN or AF cooling, indoor or outdoor enclosure, protection degree IP00, IP21 or IP23, and an optional electrostatic shield. Connection, vector group, impedance and tap configuration are matched to the project single-line diagram.

Materials and Structure

The core is built from high-quality grain-oriented electrical steel with an optimized magnetic circuit. Windings use high-conductivity copper or aluminum conductors with reinforced insulation, supported by a high-performance insulation system that may include epoxy resin, Nomex, polyester insulation and high-temperature insulating paper. An optional copper or aluminum electrostatic shielding layer between primary and secondary windings reduces common-mode noise. The heavy-duty powder-coated steel enclosure provides mechanical protection for long-term operation.

Applications

  • Data centers: UPS, PDU and critical power distribution
  • Industrial manufacturing: production lines, automation and control equipment
  • Commercial buildings: offices, hotels and shopping centers
  • Oil and gas, petrochemical process plants
  • Renewable energy: solar PV, battery energy storage and inverter systems
  • Transportation and infrastructure: railway, airport and metro projects

Customization

Primary and secondary voltages, rated capacity, impedance, connection type, vector group, tap range, temperature rise, cooling method and enclosure protection degree can all be configured to the application. Units are designed and manufactured to applicable IEC, IEEE, ANSI and UL requirements according to the target market.

FAQ

What capacity range is available for this three-phase isolation transformer?

Rated capacity spans 1 kVA to 5,000 kVA, with primary voltage up to 15 kV and secondary voltage from 120 V to 690 V, both customizable.

Which connection types and vector groups can be supplied?

Delta, Wye or Zig-Zag connections are available, and the vector group is customized according to the application.

What cooling and enclosure options are offered?

AN or AF cooling, indoor or outdoor enclosure, and protection degree IP00, IP21 or IP23, with other ratings available on request.

Can the transformer be built to IEC, IEEE, ANSI or UL requirements?

Yes. Units are designed and manufactured according to the applicable IEC, IEEE, ANSI and UL standards required by the destination market.

Is electrostatic shielding available?

An optional copper or aluminum shielding layer can be placed between primary and secondary windings to reduce common-mode noise and electrical interference.

What quality management systems cover production?

The manufacturer operates ISO 9001, ISO 14001 and ISO 45001 certified management systems, with incoming material inspection, critical process control and finished-product testing before shipment.

Inquiry Information

Contact: Yu Cao

Email: info@js-firstpower.com

Tel: +86 130 7404 8223 · WhatsApp: +86 150-0369-3908

Web: www.firstpowerglobal.com

Please share your single-line diagram, primary and secondary voltage, rated capacity, connection and vector group, enclosure and protection degree so a configuration can be prepared.

Image Filename and Alt Suggestions

isolation-transformer-fpit-three-phase-front-view.png — Alt: FPIT three-phase isolation transformer unit front view

isolation-transformer-fpit-three-phase-enclosure.png — Alt: FPIT three-phase isolation transformer powder-coated steel enclosure

Images shown are of the FPIT isolation transformer series. Configuration, enclosure and protection degree are selected per project.